Surface Plasmon Resonance Assay Services

SPR analysis for protein & small-molecule binding interactions

SPR Assay Service Overview

Surface Plasmon Resonance (SPR) is an optical technology that can detect biomolecular interactions in real time by measuring changes in the refractive index near a sensor surface. This allows for label-free analysis of binding response events between biomolecules, providing precise information on affinity determination, kinetic parameters, and equilibrium dissociation constants (Kd). SPR is widely used in high-throughput screening for drug discovery, fragment screening, and for screening therapeutic antibodies candidates, characterizing molecular interactions, and optimizing binding affinities.

SPR can analyze the binding specificity between biomolecules and perform concentration quantification, affinity determination, kinetic analysis, thermodynamic analyses, and antibody characterization without the need for additional detection reagents, truly reflecting interaction conditions. With its high-throughput, high flexibility, and high sensitivity, SPR has become an important diagnostic method in immunodetection, early drug development, drug-target interactions, and preclinical drug screening. KACTUS offers experienced surface plasmon resonance services, customized for various experimental protocols to meet the unique needs of your research.

SPR Assay Service Highlights

Diverse Sample Pairs

Full Assay Development

2-5 Day Turnaround

Regulatory Filing Support


Request Quote →

SPR Service Workflow & Timeline

Understand Testing Requirements

Workscope Discussion

Sign Contract

Contract Sign-off

Develop Method

Method Development

Test Sample

Sample Testing

Deliver Data

Delivery

Standard Sample

Includes standard proteins and monoclonal antibodies up to 5 sample pairs

2-3 Days

Complex Samples

Includes VLPs, small molecules, or peptides up to 5 sample pairs

3-5 Days


Request Quote →

Procedure Compliant with Regulatory Filing Support

At KACTUS, we are committed to ensuring that our SPR assay development services adhere to the highest standards of regulatory compliance. Our procedures encompass strict supply and management standards for reagents and consumables, meticulous usage records, calibration reports, and regular maintenance for equipment. We prioritize the reliability and integrity of our data through dual backup systems and maintain thorough experimental records in both electronic and paper formats. This rigorous approach guarantees the accuracy and dependability of our SPR analyses, providing you with reliable results for your research and development needs.

Antibody / Protein

Reagents & Consumables:
Strict Material Supply Management

Protein / Protein

Equipment:
Usage Records, Calibration Reports, & Regular Maintenance

Raw Data Icon

Raw Data Storage:
Dual Backup Systems for Enhanced Reliability

Experimental Records Icon

Experimental Records:
Documented in Both Paper and Electronic Copy


Request Quote →

Key Features & Service Advantages

1. Various Protein-Analyte Combinations

SPR is a versatile tool suitable for analyzing the binding interaction between various types of molecules. We offer SPR analysis of the following sample pairs:

Antibody / Protein

Antibody / Protein

Protein / Protein

Protein / Protein

Peptide / Protein

Protein / Peptide

Protein / Small Molecule

Protein / Small Molecule



2. Flexible Detection Methods

Covalent Immobilization:

Direct Fixation SPR Methodology

Proteins are covalently immobilized on the chip surface through amine coupling. This coupling method involves a reaction with the amino groups of the ligand protein. Generally, amine coupling is used when there are label conflicts with the substances being analyzed.

Non-covalent Immobilization:

SPR Capture Method Methodology

Non-covalent methods rely on specific, high-affinity interactions between the protein and a capture molecule on the chip. This approach is excellent for maintaining the correct orientation of the immobilized protein and for recycling the chip surface (except for SA-biotin).

3. Technical Expertise

KACTUS SPR Detection Platform is supported by a professional and experienced research team dedicated to developing and optimizing SPR assays. Through strict quality control of our extensive product catalog, our team has accumulated significant technical expertise in SPR analysis, ensuring the quality of our deliverables and an excellent customer experience.


Request Quote

SPR Analysis Case Studies

SPR Detection of VLP-Displayed Antigens

To address the challenge of conducting multiple affinity tests on difficult-to-express transmembrane proteins, KACTUS has specially developed biotinylated virus-like particle (VLP)-displayed antigens to meet the experimental requirements of SPR.

Claudin 18.2 VLP SPR Data

Figure 1. Biotinylated Human Claudin 18.2 VLP captured on CM5 Chip via Streptavidin can bind Anti-Claudin 18.2 Antibody with an affinity constant of 1.28 nM as determined in SPR assay.

GPRC5D VLP SPR Data

Figure 2. Biotinylated Human GPRC5D VLP captured on SA Chip can bind Anti-GPRC5D antibody, hFc with an affinity constant of 0.30 nM as determined in SPR assay.

Affinity Detection of Fc Receptor Proteins and Antibodies

Fc receptors are receptor proteins that can bind to the Fc region of antibodies, playing an important role in the screening and efficacy evaluation of antibody drugs. However, this binding interaction is often weak and difficult to effectively assess with conventional detection methods such as ELISA. Therefore, it necessitates the use of methods with higher sensitivity, such as SPR, for detection.

Fc gamma RI SPR Data

Figure 3. Human Fc gamma RI, His Tag captured on CM5 Chip via anti-his antibody can bind Trastuzumab with an affinity constant of 1.94 nM as determined in SPR assay.

FcRn SPR Assay Data

Figure 4. Human FcRn, His Tag captured on CM5 Chip via anti-his antibody can bind Human IgG1 Fc, No Tag with an affinity constant of 0.28 μM as determined in SPR assay.

Affinity Detection of TCR and MHC Peptide Complexes

The detection of the affinity between TCR and MHC peptide complexes is a crucial part of the development of TCR-related drugs, with SPR being a highly effective method for this detection. KACTUS offers SPR detection services to support the development of TCR-related drugs, in addition to our custom expression services for soluble TCRs.

HLA-A*02:01 monomer binding to TCR SPR Data

Figure 5. Human HLA-A*02:01&B2M&AFP (FMNKFIYEI) Monomer, His Tag captured on CM5 Chip via Anti-His Antibody can bind HLA-A*02:01&B2M&AFP (FMNKFIYEI) TCR with an affinity constant of 0.923 μM as determined in SPR assay.

HLA-A*02:01 binding to TCR in SPR Assay Data

Figure 6. Human HLA-A*02:01&B2M&GP100 (YLEPGPVTA) Tetramer, His Tag immobilized on CM5 Chip can bind gp100 TCR&Anti-CD3 bispecific fusion protein with an affinity constant of 0.196 nM as determined in SPR assay.



Request Quote

Membrane Proteins

Custom membrane proteins displayed on VLPs or Nanodiscs.

Soluble TCR Expression

Soluble TCR Expression services with engineering, and optimization of various formats of TCRs.

SPR Analysis Services

Characterization of biomolecular interactions using Surface Plasmon Resonance technology.

SPR Service Request Form:

Have questions? Talk to us!